Data Acquisition Modules, Data Acquisition Modules S140, 16 Analog Input Module The DAM140 is for monitoring 16 analog inputs( 0~ 20mA, 4~ 20mA, 0~ 5V, 0~ 10V) . It supports Modbus RTU Protocol over RS485 serial port. Powered up by 10~ 30VDC. Brief instruction The DAM140 is for monitoring 16 analog inputs( 0~ 20mA, 4~ 20mA, 0~ 5V, 0~ 10V) . It supports Modbus RTU Protocol over RS485 serial port. Powered up by 10~ 30VDC. The DAM140 is used widely in industrial automation control systems. E.g.: Base Transceiver Station, diesel generator rooms, engine room, transformer substations, telecommunication equipment rooms, power supply systems and so on. The DAM140 is an industrial class, high reliability, low-power consumption, high stability and high precision data acquisition module. The DAM140 with fire retardant shell, standard 35mm DIN rail makes it easy to install in fields Mainly Features 16-bit resolution high precision AD acquisition and data processing techniques; 16 analog input, can be 0~ 20mA, 4~ 20mA, 0~ 5V, 0~ 10V; Wide range power supply with reverse polarity connection protection; Modbus RTU Protocol; ESD Protection circuit for RS485 serial port; Using industrial-grade chips; Built-in watchdog ensure it reliability; Lightning protection ensure it stability; LEDs for status indication makes it easy to program in filed. Specifications Items : Specifications Rated Power Input : 10~ 30VDC( Peak Voltage mustd40V) Power Consumption : Typically d3W Communication Protocol : Modbus RTU Modbus Address : 1~ 247 Data Format : n, 8, 1; e, 8, 1; o, 8, 1 or n, 8, 2 Communication Interface : RS485 Baud Rate : 1200, 2400, 4800, 9600, 19200, 38400Bps Analog Input : Default: 4~ 20mA, optional: 0~ 20mA, 0~ 5V, 0~ 10V Update Period : 0.12~ 2.4S Measurement Precision : 0.2% FS Input Resistance : Analog channel: Voltage:  1K , current d150 Overload Capacity : 1.2 times can sustained, 3 times voltage can last 1 second. Isolated Type : Input / power / RS485 Serial port / drivable output use the same GND, no isolated. Withstand Tests : Input / Shell: 2000VAC/ min.; 500VDC> 100 M Installation Type : 35mm DIN Rail Operation Temperature : -20~ 70 ; Storage Temperature : -40~ 85 ; Relative Humidity : 5~ 95% RH.; ( at -40 , non condensate) Altitude : 0~ 3000m Temperature Drift : d100ppm/  Dimension : 118 72 59mm mm( HxWxD) Net Weight : 160g.
Tampilkan Lebih Banyak