Detail Data Acquisition Modules, Data Acquisition Modules S100, 2 Analog Input Module
Data Acquisition Modules, Data Acquisition Modules S100 , 2 Analog Input Module
The DAM100 is for monitoring 2 analog inputs( 0~ 20mA, 4~ 20mA, 0~ 5V, 0~ 10V, or AC and DC 0~ 5A, 0~ 500V) . It supports Modbus RTU Protocol over RS485 serial port. Powered up by 10~ 30VDC.
Introduction :
The DAM100 is for monitoring 2 analog inputs( 0~ 20mA, 4~ 20mA, 0~ 5V, 0~ 10V, or AC and DC 0~ 5A, 0~ 500V) . It supports Modbus RTU Protocol over RS485 serial port. Powered up by 10~ 30VDC.
The DAM100 is used widely in industrial automation control systems. E.g.: Base Transceiver Station, diesel generator rooms, engine room, transformer substations, telecommunication equipment rooms, power supply systems and so on.
The DAM100 is an industrial class, isolated design, high reliability, low-power consumption, high stability and high precision data acquisition module.
The DAM100 with fire retardant shell, standard 35mm DIN rail makes it easy to install in fields.
Mainly Features:
16-bit resolution high precision AD acquisition and data processing techniques;
2 analog input, can be 0~ 20mA, 4~ 20mA, 0~ 5V, 0~ 10V or AC and DC 0~ 5A, 0~ 500V;
Wide range power supply with reverse polarity connection protection;
Modbus RTU Protocol;
ESD Protection circuit for RS485 serial port;
Using industrial-grade chips;
Built-in watchdog ensure it reliability;
Lightning protection ensure it stability;
LEDs for status indication makes it easy to program in filed.
Specifications:
Items : Specifications
Rated Power Input : 10~ 30VDC( Peak Voltage mustd40V)
Power Consumption : Typically d3W
Communication Protocol : Modbus RTU
Modbus Address : 1~ 247
Data Format : n, 8, 1; e, 8, 1; o, 8, 1 or n, 8, 2
Communication Interface : RS485
Baud Rate : 1200, 2400, 4800, 9600Bps
Analog Input : Default: 4~ 20mA, optional: 0~ 20mA, 0~ 5V, 0~ 10V, 0~ 5A, 0~ 500V
Update Period : 0.1~ 1S
Measurement Precision : 0.2% FS
Input Resistance : Analog channel: Voltage: 1K , current d150
Overload Capacity : 1.2 times can sustained, 3 times voltage can last 1 second.
Isolated Type : 2500VDC Input / power / RS485 Serial port isolated.
Withstand Tests : Input / Shell: 2000VAC/ min.; 500VDC> 100 M
Installation Type : 35mm DIN Rail
Operation Temperature : -20~ 70 ;
Storage Temperature : -40~ 85 ;
Relative Humidity : 5~ 95% RH.; ( at -40 , non condensate)
Altitude : 0~ 3000m
Temperature Drift : d100ppm/
Dimension : 118 36 59mm mm( HxWxD)
Net Weight : 160g.
Tampilkan Lebih Banyak