Back to Top

Hi, Guest!

Data Acquisition Modules, Data Acquisition Modules S100, 2 Analog Input Module

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Rantai
Dilihat Sebanyak
:
16 kali
Harga
Rp. 1.400.000
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Data Acquisition Modules, Data Acquisition Modules S100, 2 Analog Input Module

Data Acquisition Modules, Data Acquisition Modules S100 , 2 Analog Input Module The DAM100 is for monitoring 2 analog inputs( 0~ 20mA, 4~ 20mA, 0~ 5V, 0~ 10V, or AC and DC 0~ 5A, 0~ 500V) . It supports Modbus RTU Protocol over RS485 serial port. Powered up by 10~ 30VDC. Introduction : The DAM100 is for monitoring 2 analog inputs( 0~ 20mA, 4~ 20mA, 0~ 5V, 0~ 10V, or AC and DC 0~ 5A, 0~ 500V) . It supports Modbus RTU Protocol over RS485 serial port. Powered up by 10~ 30VDC. The DAM100 is used widely in industrial automation control systems. E.g.: Base Transceiver Station, diesel generator rooms, engine room, transformer substations, telecommunication equipment rooms, power supply systems and so on. The DAM100 is an industrial class, isolated design, high reliability, low-power consumption, high stability and high precision data acquisition module. The DAM100 with fire retardant shell, standard 35mm DIN rail makes it easy to install in fields. Mainly Features: 16-bit resolution high precision AD acquisition and data processing techniques; 2 analog input, can be 0~ 20mA, 4~ 20mA, 0~ 5V, 0~ 10V or AC and DC 0~ 5A, 0~ 500V; Wide range power supply with reverse polarity connection protection; Modbus RTU Protocol; ESD Protection circuit for RS485 serial port; Using industrial-grade chips; Built-in watchdog ensure it reliability; Lightning protection ensure it stability; LEDs for status indication makes it easy to program in filed. Specifications: Items : Specifications Rated Power Input : 10~ 30VDC( Peak Voltage mustd40V) Power Consumption : Typically d3W Communication Protocol : Modbus RTU Modbus Address : 1~ 247 Data Format : n, 8, 1; e, 8, 1; o, 8, 1 or n, 8, 2 Communication Interface : RS485 Baud Rate : 1200, 2400, 4800, 9600Bps Analog Input : Default: 4~ 20mA, optional: 0~ 20mA, 0~ 5V, 0~ 10V, 0~ 5A, 0~ 500V Update Period : 0.1~ 1S Measurement Precision : 0.2% FS Input Resistance : Analog channel: Voltage:  1K , current d150 Overload Capacity : 1.2 times can sustained, 3 times voltage can last 1 second. Isolated Type : 2500VDC Input / power / RS485 Serial port isolated. Withstand Tests : Input / Shell: 2000VAC/ min.; 500VDC> 100 M Installation Type : 35mm DIN Rail Operation Temperature : -20~ 70 ; Storage Temperature : -40~ 85 ; Relative Humidity : 5~ 95% RH.; ( at -40 , non condensate) Altitude : 0~ 3000m Temperature Drift : d100ppm/  Dimension : 118 36 59mm mm( HxWxD) Net Weight : 160g.
Tampilkan Lebih Banyak