Detail Data Acquisition Modules, Data Acquisition Modules S124, 4 Digital Input + 8 Analog Input + 4 Digital Ouput Module
Data Acquisition Modules, Data Acquisition Modules S124, 4 Digital Input + 8 Analog Input + 4 Digital Ouput Module
The DAM124 is for monitoring 4 digital inputs( can be used as pulse counter) , 8 analog inputs, controlling 4 triode drivable digital output( 50V/ 100mA, can be TTL or Pulse output) . It supports Modbus RTU Protocol over RS485 serial port. Powered up by 10~ 30VDC
Introduction :
The DAM124 is for monitoring 4 digital inputs( can be used as pulse counter) , 8 analog inputs, controlling 4 triode drivable digital output( 50V/ 100mA, can be TTL or Pulse output) . It supports Modbus RTU Protocol over RS485 serial port. Powered up by 10~ 30VDC.
The DAM124 is used widely in industrial automation control systems. E.g.: Base Transceiver Station, diesel generator rooms, engine room, transformer substations, telecommunication equipment rooms, power supply systems and so on.
The DAM124 is an industrial class, high reliability, low-power consumption, high stability and high precision data acquisition module.
The DAM124 with fire retardant shell, standard 35mm DIN rail makes it easy to install in fields.
Mainly Features
16-bit resolution high precision AD acquisition and data processing techniques;
4 digital input, Dry contact or Wet contact( logic: 0~ 0.5V or NC= 0, + 3~ 30V or NO= 1, input voltage range: 0~ 30V, Input Max. voltage range: -10~ 40V) , can be used as pulse counter input: counter sampling frequency: 1KHz, impulse width of high or low level must > 1mS, Max. counter value is 4 bytes: FFFFFFFFH;
8 analog input, can be 0~ 20mA, 4~ 20mA, 0~ 5V, 0~ 10V;
4 drivable digital output( triode, not relay inside, 50V/ 100mA) , can be setup as TTL output or Pulse output( impulse width 0.1~ 20S) ;
Wide range power supply with reverse polarity connection protection;
Modbus RTU Protocol;
ESD Protection circuit for RS485 serial port;
Using industrial-grade chips;
Built-in watchdog ensure it reliability;
Lightning protection ensure it stability;
LEDs for status indication makes it easy to program in filed.
Specifications
Items : Specifications
Rated Power Input : 10~ 30VDC( Peak Voltage mustd40V)
Power Consumption : Typically d3W
Communication Protocol : Modbus RTU
Modbus Address : 1~ 247
Data Format : n, 8, 1; e, 8, 1; o, 8, 1 or n, 8, 2
Communication Interface : RS485
Baud Rate : 1200, 2400, 4800, 9600, 19200, 38400Bps
Digital Input : 8 digital input, Dry contact or Wet contact
Drivable Output : 4 drivable digital output( triode, not relay inside, 50V/ 100mA)
Analog Input : Default: 4~ 20mA, optional: 0~ 20mA, 0~ 5V, 0~ 10V
Update Period : 0.25~ 2S
Measurement Precision : 0.1% FS
Input Resistance : Analog channel: Voltage: 1K , current d150
Overload Capacity : 1.2 times can sustained, 3 times voltage can last 1 second.
Isolated Type : Digital Input / power / RS485 Serial port / drivable output use the same GND, no isolated.
Withstand Tests : Input / Output / Shell: 2000VAC/ min.; 500VDC> 100 M
Installation Type : 35mm DIN Rail
Operation Temperature : -20~ 70 ;
Storage Temperature : -40~ 85 ;
Relative Humidity : 5~ 95% RH.; ( at -40 , non condensate)
Altitude : 0~ 3000m
Temperature Drift : d100ppm/
Dimension : 118 72 59mm mm( HxWxD)
Net Weight : 160g.
Tampilkan Lebih Banyak