Detail Data Acquisition Modules, Data Acquisition Modules S126, 6 Digital Input And 16 Digital Output Relay Module
Data Acquisition Modules, Data Acquisition Modules S126, 6 Digital Input and 16 Digital Output Relay Module
The DAM126 is for monitoring 6 digital input( can be used as pulse counter) , controlling 16 relay output( can be TTL or Pulse output) . It supports Modbus RTU Protocol over RS485 serial port. Powered up by 10~ 30VDC.
Brief instruction
The DAM126 is for monitoring 6 digital input( can be used as pulse counter) , controlling 16 relay output( can be TTL or Pulse output) . It supports Modbus RTU Protocol over RS485 serial port. Powered up by 10~ 30VDC.
The DAM126 is used widely in industrial automation control systems. E.g.: Base Transceiver Station, diesel generator rooms, engine room, transformer substations, telecommunication equipment rooms, power supply systems and so on.
The DAM126 is an industrial class, high reliability, low-power consumption, high stability and high precision data acquisition module.
The DAM126 with fire retardant shell, standard 35mm DIN rail makes it easy to install in fields.
Mainly Features:
6 digital input, Dry contact or Wet contact( logic: 0~ 0.5V or NC= 0, + 3~ 30V or NO= 1, input voltage range: 0^ 30V, Input Max. voltage range: -10^ 40V) , can be used as pulse counter input: counter sampling frequency: 1KHz, impulse width of high or low level must > 1mS, Max. counter value is 4 bytes: FFFFFFFFH;
16 relay output( Rated 250VAC@ 5A or 30VDC@ 5A, 14 relay outputs are NO type, 2 relay outputs are NC and NO type.) , can be setup as TTL output or Pulse output( impulse width 0.1~ 20S) ;
Wide range power supply with reverse polarity connection protection;
Modbus RTU Protocol;
ESD Protection circuit for RS485 serial port;
Using industrial-grade chips;
Built-in watchdog ensure it reliability;
Lightning protection ensure it stability;
LEDs for status indication makes it easy to program in filed.
Specifications
Items : Specifications
Rated Power Input : 10~ 30VDC( Peak Voltage mustd40V)
Power Consumption : Typically d3W
Communication Protocol : Modbus RTU
Modbus Address : 1~ 247
Data Format : n, 8, 1; e, 8, 1; o, 8, 1 or n, 8, 2
Communication Interface : RS485
Baud Rate : 1200, 2400, 4800, 9600, 19200, 38400Bps
Digital Input : 8 digital input, Dry contact or Wet contact
Relay Output : 16 relay output( Rated 250VAC@ 5A or 30VDC@ 5A, 14 relay outputs are NO type, 2 relay outputs are NC and NO type. )
Isolated Type : Digital Input / power / RS485 Serial port / relay outputs use the same GND, not isolated
Withstand Tests : Input / Output / Shell: 2000VAC/ min.; 500VDC> 100 M
Installation Type : 35mm DIN Rail
Operation Temperature : -20~ 70 ;
Storage Temperature : -40~ 85 ;
Relative Humidity : 5~ 95% RH.; ( at -40 , non condensate)
Altitude : 0~ 3000m
Temperature Drift : d100ppm/
Dimension : 118 107 59mm ( HxWxD)
Net Weight : 200g.