Detail Data Acquisition Modules, Data Acquisition Modules S204, 4 Channel Analog Output Module
Data Acquisition Modules, Data Acquisition Modules S204 , 4 Channel Analog Output Module
The DAM204 is convert 4-channel analog output signal 4^ 20mA, 0^ 20mA, 0^ 5V, or 0^ 10V from any RTU, SCADA, data monitoring, data loggers, PLC? s, process controllers, instrumentation that supports Modbus RTU Protocol over RS485 serial port. and transmit in ASCII data format to engineering units for control equipments. It is an industrial class, high reliability, low-power consumption, high stability
Introduction :
The DAM204 is convert 4-channel analog output signal 4^ 20mA, 0^ 20mA, 0^ 5V, or 0^ 10V from any RTU, SCADA, data monitoring, data loggers, PLC? s, process controllers, instrumentation that supports Modbus RTU Protocol over RS485 serial port. and transmit in ASCII data format to engineering units for control equipments. It is an industrial class, high reliability, low-power consumption, high stability and high precision control module. Powered up by 12VDC or 24VDC.
The DAM204 is used widely as an extension control module in of Base Transceiver Station, diesel generator rooms, engine room, transformer substations, telecommunication equipment rooms, power supply systems and so on.
The DAM204 with fire retardant shell, standard 35mm DIN rail makes it easy to install in fields.
Mainly Features
Power supply with reverse polarity connection protection;
Modbus RTU Protocol;
ESD Protection circuit for RS485 serial port;
Using industrial-grade chips;
Built-in watchdog ensure it reliability;
Lightning protection ensure it stability;
LEDs for status indication makes it easy to program in filed.
Specifications
Items : Specifications
Rated Power Input : 12VDC( Default) or 24VDC( Optional)
Power Consumption : Typically d1W
Communication Protocol : Modbus RTU
Modbus Address : 1~ 247
Data Format : n, 8, 1; e, 8, 1; o, 8, 1 or n, 8, 2
Communication Interface : RS485
Baud Rate : 1200, 2400, 4800, 9600Bps
Analog Output Channel : 4
Analog Output Signal : Default: 4^ 20mA; Optional: 0^ 20mA, 0^ 5V, or 0^ 10V
Output Response Time : 100^ 200mS
Overload Capacity : 1.1 times of the output
Output Precision : 0.2% FS or 0.5% FS
Isolated Type : Input / power / RS485 Serial port isolated
Withstand Tests : Input / Output / Shell: 2000VAC/ min.; 500VDC> 100 M
Installation Type : 35mm DIN Rail
Operation Temperature : -20~ 70 ;
Storage Temperature : -40~ 85 ;
Relative Humidity : 5~ 95% RH.; ( at -40 , non condensate)
Altitude : 0~ 3000m
Temperature Drift : d100ppm/
Dimension : 118 72 59mm mm( HxWxD)
Net Weight : 105g.